본문바로가기

All

Acuros®6 CQD® SWIR Camera

세계 최초의 6MP CQD SWIR 카메라 소개
SWIR Vision Systems는 Acuros® 6 SWIR 머신 비전 카메라를 통해 메가픽셀당 최저 비용의 전통을 이어갑니다. 작고 가벼운 디자인은 UV에서 최대 2.1μm까지의 스펙트럼 응답을 제공하며 향상된 SNR 성능을 위해 광학적으로 향상된 CQD 기술을 갖춘 7μm 픽셀을 갖추고 있습니다. 단일 스테이지 TEC는 광범위한 작동 조건에서 안정적인 성능을 보장합니다.

  • • Compact form factor
    • 10GigE and CoaXPress interface options
    • Auto Exposure
    • Dynamic Non-Uniformity Corrections (NUCs) 
    • GenICam Compliant
    • TEC thermal stabilization (uncooled)
    • Spectral range covering UV-2.1µm
  • Sensor Features 
    Type Acuros® 6 CQD sensor
    Pixel Pitch 7 µm
    Format 3064 x 2040
    Array Size 21.50 mm x 14.34 mm
    Array Diagonal 25.84 mm
    Shutter Global Shutter
    Max FPS (full frame) 100 Hz (8 bit), 50 Hz (12 bit), 
    Min Exposure time 10 µs
    Detector Technology Colloidal quantum dot photodiode
    Detector type SWIR eSWIR 
    Spectral Range 400-1700 nm 400-2100 nm
    QE >20% @ 1550 nm >15% @ 1900 nm
    Pixel operability 99.9% typical
    Dark noise (at 30C) TBD (e/s) TBD (e/s)
    Dark noise doubling temp 20 C 18 C
    Analog Gain Modes Low Gain High Gain 
    Read noise 125 e- 20 eWell-depth 350 Ke- 52 KeDynamic Range 68 db 63 db
    ADC bit depth 8-bit or 12-bit
    Camera Features 
    Trigger External TTL via SMA
    Region of interest (ROIC) Yes (8 row increments)
    ROI FPS scaling Yes. FPS up to 10 KHz for 3064 x 8 pixel ROI 
    Binning arrays Yes
    Non-uniformity correction 2 pt
    Auto exposure control Yes
    Environmental & power specifications, typical performance 
    Sensor temperature stabilization Single-stage TEC
    Operating case temperature -40 °C to +85 °C
    Storage temperature -40 °C to +125 °C
    Power consumption Data coming soon
    Power supply voltage Data coming soon
    Mechanical specifications 
    Dimensions excluding lens 5 cm x 5 cm x 8 cm
    Weight excluding lens 300 g
    Lens mounts C-mount, M42-C
    Power connector 8-pin M8 connector
    Trigger connector SMA
    Software and user interface 
    Software development kit Euresys eGrabber SDK
    GenICam compliance Yes
    Interface 10GigE or CoaXPress (CXP-6)



  • • Machine vision 
    • Silicon inspection 
    • Laser beam profiling
    • Automotive 
    • Surveillance 
    • Hyperspectral 
    • Chemical sensors
    • Agricultural 
    • Medical imaging 
    • Thermography